Lifting precautions
Make sure the rack or cabinet housing the device is adequately secured to prevent it from
becoming unstable or falling over.
Mount the devices in the lowest possible slots in a rack or cabinet. Place the heaviest device at
the bottom and progressively place lighter devices above.
Power precautions
Use a separate branch circuit for each AC power cable, which provides redundancy in case one of
the circuits fails.
To avoid high voltage shock, do not open the device while the power is on.
Ensure that the device does not overload the power circuits, wiring, and over-current protection.
To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all
devices installed on the same circuit as the device. Compare this total with the rating limit for the
circuit. The maximum ampere ratings are usually printed on the devices near the input power
connectors.
Disconnect the power cable from all power sources to completely remove power from the device.
If the installation requires a different power cable than the one supplied with the device, make
sure you use a power cable displaying the mark of the safety agency that defines the regulations
for power cords in your country. The mark is your assurance that the power cable can be used
safely with the device.